Endress+Hauser Prosonic FMU42: Ultrasonic Level Measurement for Larger Tanks and Bulk Solids

News October 16, 2026
Endress+Hauser Prosonic FMU42
Ultrasonic Level Measurement for Larger Tanks and Bulk Solids

Choosing a level transmitter starts with the vessel, the medium and the conditions above the product surface. For applications that need greater ultrasonic reach than smaller compact models, the Prosonic FMU42 offers a non-contact approach with a flange process connection.

MEASUREMENT RANGE FOR EVERYDAY PROCESS TASKS

The FMU42 uses ultrasonic time-of-flight measurement for fluids, pastes and coarse bulk materials. It also supports flow monitoring in open channels or at weirs. Maximum distances reach 10 m for liquids and 5 m for solids. A 0.4 m blocking distance must remain clear below the sensor face. Actual performance depends on the application and installation.

KEY TECHNICAL HIGHLIGHTS

• Maximum measuring distance: liquids 10 m; solids 5 m
• Blocking distance: 0.4 m
• Process temperature: -40 to +80 °C
• Process pressure: 0.7 to 2.5 bar absolute
• Main wetted material: PVDF
• Process connection: flange
• Two-wire or four-wire transmitter versions

DIAGNOSTICS THAT SUPPORT COMMISSIONING

An echo envelope curve can be viewed on the local display to assist diagnosis. Up to 32 linearization points allow conversion into length, volume or flow values. The electronics, output and approvals should be checked against the complete order code.

INSTALLATION DETAILS THAT MATTER

For a tank installation, check the flange arrangement, nozzle dimensions and the clear path between the sensor and product surface. Internal structures, filling streams and agitators should be considered when selecting the mounting position. Keep the highest expected surface outside the blocking distance.

Foam, heavy dust, turbulence and vapour can affect ultrasonic echoes. Assess the usable measuring distance under real operating conditions rather than selecting solely from the nominal range. For bulk solids, consider the surface profile and filling pattern; for open-channel flow, confirm the measuring location and channel or weir geometry.

PREPARING AN FMU42 ENQUIRY

For an existing installation, send a clear nameplate photo and full order code. For a new project, provide the medium, range, vessel drawing, temperature, pressure, flange requirements, output, approvals and quantity. This helps identify the appropriate configuration before an order is placed.