E+H FMR30B Radar Level Update: Why Complete Order Codes Matter
Product & Technical Insights | September 14, 2026
For industrial maintenance and project teams, a level-instrument enquiry can lose valuable time before the first quotation arrives: the request names a product family but omits its configuration. Our latest Endress+Hauser update focuses on the E+H Micropilot FMR30B radar level transmitter and a practical way to make technical reviews and purchasing enquiries more precise.
At a glance: FMR30B is an 80 GHz non-contact radar instrument for continuous level measurement in liquids and solids. For a quotation, send your complete ordering reference, such as FMR30B-AABAKHBMXQ0VEE3, not simply “FMR30B.” The family name identifies the platform; the full code identifies the configuration to be checked.

E+H portfolio illustration from our existing photo library. Confirm the exact instrument and configuration from the order code, not the image alone.
Technical Insights: What FMR30B Brings to Basic Level Applications
Endress+Hauser positions Micropilot FMR30B for basic liquid and solid level duties, including utility and storage applications. Published family specifications include 80 GHz radar, two-wire 4–20 mA/HART communication, and a maximum measuring distance of 20 m with the 40 mm antenna or 30 m with the 80 mm antenna. The stated accuracy is ±2 mm for liquids and ±4 mm for solids. The published process envelope is −40 to +80°C and −1 to +3 bar.
The family also offers guided commissioning, a color touch display, optional Bluetooth access with SmartBlue, and Heartbeat verification and diagnostics. These are family-level reference points, not a decoded specification for FMR30B-AABAKHBMXQ0VEE3. Confirm the ordered options, applicable limits and installation requirements before approval. Source: Endress+Hauser Micropilot FMR30B overview.
Application Outlook: Better Retrofit Decisions Start with Better Enquiries
Our technical perspective: modernization should be judged by the quality of the measurement and the ease of integration, not by radar frequency alone. When reviewing an existing tank or silo installation, engineers should document the medium, measuring span, mounting arrangement, internal obstructions and available control-system interface before comparing alternatives.
A replacement project and a new installation need different starting information. For a replacement, an existing nameplate and order-code record help establish the installed configuration. For a new application, a process data sheet gives the selection review its foundation. A model copied from another tank is an enquiry example, not proof that it suits the new duty.
Why the Complete E+H Order Code Matters
A short name such as FMR30B does not, by itself, tell a buyer everything needed to identify the required instrument. Depending on the product family, configuration choices can involve process connections, materials, electrical interfaces, approvals, accessories or probe dimensions. Do not shorten the code, omit characters after “+”, or substitute a similar-looking reference without an engineering check.
Required for every enquiry:
Product family: FMR30B
Complete model: FMR30B-AABAKHBMXQ0VEE3
Also provide quantity, delivery destination and required delivery date. For replacements, attach a clear nameplate photo where available.
Supply Enquiries: Move from a Family Name to a Comparable Quotation
HKXYTECH welcomes sourcing and quotation enquiries for E+H FMR30B and the wider level-instrument range listed below. Our team can review the complete reference and requested quantity, coordinate available supply options and clarify the documentation needed for the order. Stock, lead time and delivery terms are confirmed individually; this article does not announce a fixed stock quantity or a guaranteed dispatch date.
For a multi-instrument project, send one structured list containing the complete codes, quantities and any length requirements. This helps separate an exact replacement request from an application-selection enquiry and gives buyers a clearer basis for comparing quotations.
Complete-Model Enquiry Examples: E+H Level Instrumentation
Use the following format when requesting a quotation. These supplied references illustrate complete-code enquiries across different product families; they are not interchangeable alternatives or confirmation of suitability for a particular process. Other E+H models are also welcome.
| Family / enquiry label | Complete model and length information |
|---|---|
| FMR43 | FMR43-AABADFNX1X2JGFC+TC |
| FMR20B | FMR20B-AABADTBMVCGVEEB |
| FMR10B | FMR10B-AAAADTBMWDGWEEB |
| FMR30B | FMR30B-AABAKHBMXQ0VEE3 |
| FMR67 (enquiry label; code starts FMR67B) | FMR67B-AABAFBCJGPEBESJD1+EH |
| FMR62 | FMR62-NBBCAAGMF5MRK |
| FMR60 | FMR60-AAALAAGAA3XJG |
| FWR30 | FWR30-AA1B1B7B0+PC |
| FMR20 | FMR20-AAABNWDEXR01 |
| FMR10 | FMR10-AAQBMWDEWFE2 |
| NMR84 | NMR84-IC1BB1C2B1ACABFB1AHJITD |
| NMR81 | NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3 |
| FMR67B | FMR67B-AABAENAFGAJCRBFD3 |
| FMR66B | FMR66B-AABAEDAHBSI1WFEA |
| FMR62B | FMR62B-AABACAAJGNEBEUKB+AA |
| FMR60B | FMR60B-AABAEJAFBSJCRCFA+LA |
| FMR54 | FMR54-AAACCABDD1AJJ+AAEHJALA |
| FMR52 | FMR52-BCACCBBPAGK+AA |
| FMR51 | FMR51-BBACCABCA5AGJ |
| FMP50 | FMP50-BCACCBAAA1GDJ+AAF371,2M |
| FMP51 | FMP51-BAACCABCB3ARJ+AA, 7000MM |
| FMP52 | FMP52-AAACCAOACHK+AAIJZ1 (2050MM) |
| FMP53 | FMP53-AAACCADAB5TDJ L=560 mm |
| FMP54 | FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM) |
| FMP55 | FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM |
| FMP56 | FMP56-AAAAAALAABGDE |
| FMP57 | FMP57-AAACCAAEA4GGE (2000mm) |
| FMU40 | FMU40-ARB2A2 |
| FMU41 | FMU41-1NB2A2 |
| FMU42 | FMU42-AVB2A42A |
| FMU44 | FMU44-ATB2A23A |
| FMU30 | FMU30-AAHEAAGGF |
| FMG50 | FMG50-AABADJACA |
Code-check note: the example labelled FMR67 contains an FMR67B ordering code. Please confirm which generation is required instead of treating the two names as identical. For probe instruments, retain every length value and unit shown in your documentation. If a character, separator or suffix is unclear, send the nameplate or original order sheet for verification.
Frequently Asked Questions
Is “E+H FMR30B” enough to obtain an exact quotation?
No. Send the complete ordering code, for example FMR30B-AABAKHBMXQ0VEE3, together with quantity and destination. If the full code is unavailable, send a nameplate image or application data so the requirement can be clarified.
Does every FMR30B measure up to 30 metres?
No. The manufacturer distinguishes antenna-dependent maximum ranges, and the usable range must also be assessed for the application. Confirm the exact configuration rather than applying the family maximum to every instrument.
Can I use one of the listed codes for a different application?
Only after checking the technical requirements. The examples show how to submit a complete enquiry, not which configuration to select for every tank, silo or process.
Where should I send an E+H level transmitter enquiry?
Email becky@hkxytech.com or call +86 15972186287. Include the full model, quantity, destination and any probe length or documentation requirements.
Request a configuration review or quotation
E+H FMR30B and other level-instrument enquiries
becky@hkxytech.com
+86 15972186287
A complete model today helps make tomorrow’s quotation more precise.
